30 research outputs found

    Early and mid-term outcome of patients with low-flow-low-gradient aortic stenosis treated with newer-generation transcatheter aortic valves

    Get PDF
    Patients with non-paradoxical low-flow-low-gradient (LFLG) aortic stenosis (AS) are at increased surgical risk, and thus, they may particularly benefit from transcatheter aortic valve replacement (TAVR). However, data on this issue are still limited and based on the results with older-generation transcatheter heart valves (THVs). The aim of this study was to investigate early and mid-term outcome of TAVR with newer-generation THVs in the setting of LFLG AS. Data for the present analysis were gathered from the OBSERVANT II dataset, a national Italian observational, prospective, multicenter cohort study that enrolled 2,989 consecutive AS patients who underwent TAVR at 30 Italian centers between December 2016 and September 2018, using newer-generation THVs. Overall, 420 patients with LVEF <= 50% and mean aortic gradient <40 mmHg were included in this analysis. The primary outcomes were 1-year all-cause mortality and a combined endpoint including all-cause mortality and hospital readmission due to congestive heart failure (CHF) at 1 year. A risk-adjusted analysis was performed to compare the outcome of LFLG AS patients treated with TAVR (n = 389) with those who underwent surgical aortic valve replacement (SAVR, n = 401) from the OBSERVANT I study. Patients with LFLG AS undergoing TAVR were old (mean age, 80.8 +/- 6.7 years) and with increased operative risk (mean EuroSCORE II, 11.5 +/- 10.2%). VARC-3 device success was 83.3% with 7.6% of moderate/severe paravalvular leak. Thirty-day mortality was 3.1%. One-year all-cause mortality was 17.4%, and the composite endpoint was 34.8%. Chronic obstructive pulmonary disease (HR 1.78) and EuroSCORE II (HR 1.02) were independent predictors of 1-year mortality, while diabetes (HR 1.53) and class NYHA IV (HR 2.38) were independent predictors of 1-year mortality or CHF. Compared with LFLG AS treated with SAVR, TAVR patients had a higher rate of major vascular complications and permanent pacemaker, while SAVR patients underwent more frequently to blood transfusion, cardiogenic shock, AKI, and MI. However, 30-day and 1-year outcomes were similar between groups. Patients with non-paradoxical LFLG AS treated by TAVR were older and with higher surgical risk compared with SAVR patients. Notwithstanding, TAVR was safe and effective with a similar outcome to SAVR at both early and mid-term

    Percutaneous mitral valve repair with the MitraClip system: acute results from a real world setting

    Get PDF
    This study sought to evaluate the feasibility and early outcomes of a percutaneous edge-to-edge repair approach for mitral valve regurgitation with the MitraClip((R)) system (Evalve, Inc., Menlo Park, CA, USA).Patients were selected for the procedure based on the consensus of a multidisciplinary team. The primary efficacy endpoint was acute device success defined as clip placement with reduction of mitral regurgitation to < 2+. The primary acute safety endpoint was 30-day freedom from major adverse events, defined as the composite of death, myocardial infarction, non-elective cardiac surgery for adverse events, renal failure, transfusion of > 2 units of blood, ventilation for > 48 h, deep wound infection, septicaemia, and new onset of atrial fibrillation. Thirty-one patients (median age 71, male 81%) were treated between August 2008 and July 2009. Eighteen patients (58%) presented with functional disease and 13 patients (42%) presented with organic degenerative disease. A clip was successfully implanted in 19 patients (61%) and two clips in 12 patients (39%). The median device implantation time was 80 min. At 30 days, there was an intra-procedural cardiac tamponade and a non-cardiac death, resulting in a primary safety endpoint of 93.6% [95% confidence interval (CI) 77.2-98.9]. Acute device success was observed in 96.8% of patients (95% CI 81.5-99.8). Compared with baseline, left ventricular diameters, diastolic left ventricular volume, diastolic annular septal-lateral dimension, and mitral valve area significantly diminished at 30 days.Our initial results with the MitraClip device in a very small number of patients indicate that percutaneous edge-to-edge mitral valve repair is feasible and may be accomplished with favourable short-term safety and efficacy results

    One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

    Get PDF
    The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33-0.71), in females (HR 0.57, 0.38-0.85), and among patients with EuroSCORE II >= 4.0% (HR 0.48, 95% CI 0.32-0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR

    Watchful surgery in asymptomatic mitral valve prolapse

    Get PDF
    The most common organic etiology of mitral regurgitation is degenerative and consists of mitral valve prolapse (MVP). Volume overload because of mitral regurgitation is the most common complication of MVP. Advocating surgery before the consequences of volume overload become irreparable restores life expectancy, but carries a risk of mortality in patients who are often asymptomatic. On the other hand, the post-surgical outcome of symptomatic patients is dismal and life expectancy is impaired. In the present article, we aim to bridge the gap between these two therapeutic approaches, unifying the concepts of watchful waiting and early surgery in a “watchful surgery approach”

    Percutaneous treatment of patients with heart diseases: selection, guidance and follow-up. A review

    Get PDF
    Aortic stenosis and mitral regurgitation, patent foramen ovale, interatrial septal defect, atrial fibrillation and perivalvular leak, are now amenable to percutaneous treatment. These percutaneous procedures require the use of Transthoracic (TTE), Transesophageal (TEE) and/or Intracardiac echocardiography (ICE). This paper provides an overview of the different percutaneous interventions, trying to provide a systematic and comprehensive approach for selection, guidance and follow-up of patients undergoing these procedures, illustrating the key role of 2D echocardiography

    Archivio .zip contenente il materiale didattico per gli studenti del CI di Chirurgia Generale di Rimini.

    No full text
    A causa di alcune restrizioni nel sistema di caricamento del materiale didattico, questo files é diviso in 7 parti. Per accedervi, é necessario scaricarle tutte (550+ MB) e rimetterle assieme usando un programma adatto (per esempio, winRAR)

    PANCREATITE ACUTA

    No full text

    schede riassuntive

    No full text
    corecore